Chronic Respiratory Disease

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, M K
Right arrow Articles by Banham, S W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, M K
Right arrow Articles by Banham, S W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Chronic Respiratory Disease, Vol. 1, No. 2, 83-88 (2004)
DOI: 10.1191/1479972304cd019oa

Long-term continuous positive airway pressure (CPAP) outcomes from a sleep service using limited sleep studies and daycase CPAP titration in the management of obstructive sleep apnoea/hypopnoea syndrome

M K Johnson

R Carter

A Nicol

R Paton

S W Banham

Department of Respiratory Medicine, Glasgow Royal Infirmary, Glasgow, UK

Background: Detailed polysomnography (PSG) and overnight continuous positive airway pressure (CPAP) titration as the basis for investigation and treatment of obstructive sleep apnoea/hypopnoea syndrome (OSAHS) incurs high costs from inpatient stays and technician attendance, even when split night studies are employed. Responding to rapidly increasing demand, from 1996 the sleep service at Glasgow Royal Infirmary adopted limited sleep studies and daycase CPAP titration as first line management. Here we describe the outcomes of this service between 1996 and 1999. Methods: Data were collected from prospective records made at follow up by sleep technicians and by casenote review. Results: Results were available for 158 subjects (97.5%) of 162 commenced on CPAP during this period. One hundred and forty-eight (91%) were diagnosed by limited sleep studies and 80 (50%) were diagnosed at home. The median follow up was 23 months (interquartile range (IQR), 13-35). Median use of CPAP in those continuing therapy was 5.3 hours/night (IQR, 3.1 to 6.5) and 77% were still using CPAP at three years. Only initial low CPAP compliance (< 2 hours/night) significantly predicted early CPAP cessation. In those still on CPAP in 1999, the mean drop in Epworth Sleepiness Scale score was 4.6 points (95% confidence intervals, 3.2 to 6.0). Conclusion: These data from the CPAP population at Glasgow Royal Infirmary provide information on longterm outcomes using a diagnostic protocol based on limited sleep studies and daycase CPAP titration.

Key Words: compliance • CPAP • limited sleep studies • obstructive sleep apnoea/hypopnoea syndrome


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?